| Device type | Thermostats |
| Contact type | Snap-action contact |
| Sensor | Thermostatic bimetal |
| Protection type | IP20 |
| Casing | Plastic to UL94 V-0, light grey |
| AC/DC | AC |
| Inrush current | 16 A |
| Inrush current duration | 10 s |
| Switching capacity | Normally closed: AC 10 (4) A, DC 30 W;
Normally open: AC 5 (2) A, DC 30 W |
| Switching current ohmic | 10 A(NC) |
| Switching current 2 ohmic | 5 A(NO) |
| Reference voltage ohmic | 250 VAC |
| Reference voltage 2 ohmic | 120 VAC |
| Switching current inductive | 4 A(NC) |
| Switching current 2 inductive | 2 A(NO) |
| reference_voltage_inductive | 250 VAC |
| Reference voltage 2 | 120 VAC |
| Switching current dc ohmic | 1 A |
| Reference voltage dc ohmic | 30 VDC |
| Minimal switching capacity | 0.48 W |
| Reference voltage | 24 V |
| Switching current | 10 mA |
| Service life | >100000 cycles |
| Switching differential | 5 K |
| Switching differential tolerance | -3/+2 K |
| Operating temperature | -49 °F - 149 °F |
| Operating humidity | ≤90 % rF |
| Storage humidity | ≤90 % rF |
| Storage temperature | -49 °F - 149 °F |
| Torque | 0.5 Nmmax. |
| Connection | 4-pole clamp, torque 0.5 Nm max:
Rigid wire/stranded wire² 2.5 mm² (AWG 14) |
| Design | Changer |
| Mounting | Clip for 35 mm DIN rail, EN 60715 |
| Height | 2.6 in |
| Width | 2 in |
| Depth | 1.5 in |
| Weight | 3.5 oz |
| Note | The controller's contact system is exposed to environmental influences, which can change the contact resistance. This can lead to a voltage drop and/or self-heating of the contacts. During usage of the NC (normally closed) contact, there is the possibility of thermal return to reduce the switching temperature differential by connecting the clamp "N" (RF heating resistor). It depends on the ambient conditions and must be determined in tests for the respective application. Wire end ferrules must be used for connections with stranded wires. |