Suche
RC016-1-flat-enclosure-heater-feature
RC016-1-flat-enclosure-heater-wiring-diagram

Flat enclosure heater

RC 016

Contact heater for use in small casings if the temperature must not fall below a minimum temperature and condensation is to be prevented. The heaters are designed for continuous operation.

  • Wide voltage range for electrical connection
  • PTC heating element with dynamic response behavior
  • Compact dimensions, use: e.g. as a camera heater
  • High heating capacity per volume
CEUKCAEACULVDE

Overview technical data

Device typeConvection heaters
Protection classII
Protection typeIP54
Heating elementPTC resistor (PTC)
Heater elementAluminium profile, anodised
AC/DCAC DC
Operating voltage120 V - 240 V
Operating voltage tolerance110 V - 265 V
Frequency 50;60 Hz
Operating temperature-49 °F - 158 °F
Operating humidity ≤90 % RH
Storage humidity ≤90 % RH
Storage temperature-49 °F - 158 °F
Connection typeConnection cable
MountingScrew fixing
Installation positionvariable
Height 0.5 in
Width 1 in
NoteOther voltages on request Heating capacity measured at +20°C (+68°F) ambient temperature When operating under AC/DC 140 V, the heating capacity is reduced by approx. 10 %.

Product variants

Article numberFollow-up articleInrush current maximumRecommended backup fuseHeating capacity minimumSurface temperatureConnectionDepthWeightRequestCADDatasheet
01602.0-0001651.0-002 A 2 A8 W< + 329 °F2x AWG 18 stranded wire 1.2 in 0.7 oz
RC016-01602.0-00-Datasheet-EN-US.pdf
01609.0-0001662.0-002.5 A 4 A10 W< + 311 °F2x AWG 22 cable (silicone) 2 in 0.7 oz
RC016-01609.0-00-Datasheet-EN-US.pdf
01610.0-0001673.0-002.5 A 4 A13 W< + 338 °F2x AWG 22 cable (silicone) 2.4 in 1.4 oz
RC016-01610.0-00-Datasheet-EN-US.pdf

Certificates

Your direct contact

STEGO, Inc.
95 Chastain Road NW
Suite 200 Kennesaw
GA 30144 USA