Enclosure heater with fan

HGL 046

The compact fan heater heats the air inside the enclosure or casing to protect against harmful condensation. The convection effect of this resistance heater is maximized by the integrated fan.

  • Compact convection heater
  • Resistance heating element
  • Temperature safety cut-out: overheating protection in the event of fan failure
  • Long service life
CEUKCAEACULVDE

Overview technical data

Device typeFan heater
Temperature monitoringOverheating protection in the event of fan failure with automatic reset
Protection classI
Protection typeIP20
Connection casePlastic to UL94 V-0, black
Heating elementResistance heater
Heater elementAluminium profile, anodised
AC/DCAC
Frequency 50;60 Hz
Service life>50000 h
Operating temperature-49 °F - 158 °F
Operating humidity ≤90 % RH
Storage humidity ≤90 % RH
Storage temperature-49 °F - 158 °F
Connection typeConnection terminal
ConnectionInternal connection terminal 1.5 mm² with strain relief
MountingClip for 35 mm DIN rail
Installation positionAirflow direction "in" vertical / connection at the bottom
Width 3.3 in
Depth 3.9 in
NoteOther voltages on request Note: according to UL 508A, NITW file on request

Product variants

Article numberOperating voltage minimumOperating voltage toleranceRecommended backup fuseHeating capacity minimumSurface temperatureHeightWeightRequestCADDatasheet
04640.0-00230 V208 V - 253 V 2 A250 W< + 158 °F 7.2 in 38.8 oz
HGL046-04640.0-00-Datasheet-EN-US.pdf
04640.9-00120 V108 V - 132 V 4 A250 W< + 158 °F 7.2 in 38.8 oz
HGL046-04640.9-00-Datasheet-EN-US.pdf
04641.0-00230 V208 V - 253 V 2 A400 W< + 167 °F 8.7 in 49.4 oz
HGL046-04641.0-00-Datasheet-EN-US.pdf
04641.9-00120 V108 V - 132 V 6.3 A400 W< + 167 °F 8.7 in 49.4 oz
HGL046-04641.9-00-Datasheet-EN-US.pdf