07300.0-00 | Temperature, relative humidity | IP64 | Stainless steel | -40 °F - 158 °F | ± 0,2 K | 0 % RH - 100 % RH | ± 2 % | 1: t63 <120 s / 2: t63 <20 s | -40 °F - 158 °F | Male connector M12 IEC 61076-2-101, 4-pole, A-coded | incl. pipe clip for screw fixing, Ø 3 mm | Ø 20 mm | Ø 20 mm | 1.3 in | 0.9 oz | 244445 | 244446 | 244447 | Cable 2.0 m, fully assembled with M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | Cable 5.0 m, for self-assembly, incl. M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | Cable 20.0 m, for self-assembly, incl. M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | | | SEN073-07300.0-00-Datasheet-EN-US.pdf |
07300.1-00 | Temperature, relative humidity | IP20 | Plastic to UL94 V-0, black | -40 °F - 176 °F | ± 0,2 K | 0 % RH - 100 % RH | ± 2 % | 1: t63 <90 s / 2: t63 <7 s | -40 °F - 185 °F | Cable with male connector, shielded, 1.0 m | Clip for 35 mm DIN rail, EN 60715 and M4 screw fixing | 0.5 in | 0.5 in | 2.3 in | 1.4 oz | | | | | | | | | SEN073-07300.1-00-Datasheet-EN-US.pdf |
07300.1-01 | Temperature, relative humidity | IP20 | Plastic to UL94 V-0, black | -40 °F - 176 °F | ± 0,2 K | 0 % RH - 100 % RH | ± 2 % | 1: t63 <90 s / 2: t63 <7 s | -40 °F - 185 °F | Cable with male connector, shielded, 2.0 m | Clip for 35 mm DIN rail, EN 60715 and M4 screw fixing | 0.5 in | 0.5 in | 2.3 in | 2.5 oz | | | | | | | | | SEN073-07300.1-01-Datasheet-EN-US.pdf |
07301.0-00 | Absolute air pressure, temperature | IP64 | Stainless steel | 300 hPa - 1100 hPa | ± 1,0 hPa | -40 °F - 158 °F | ± 0,5 K | 1: t63 <5 s / 2: t63 <150 s | -40 °F - 158 °F | Male connector M12 IEC 61076-2-101, 4-pole, A-coded | incl. pipe clip for screw fixing, Ø 3 mm | Ø 20 mm | Ø 20 mm | 1.3 in | 0.9 oz | 244445 | 244446 | 244447 | Cable 2.0 m, fully assembled with M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | Cable 5.0 m, for self-assembly, incl. M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | Cable 20.0 m, for self-assembly, incl. M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | | | SEN073-07301.0-00-Datasheet-EN-US.pdf |
07302.0-00 | visible light | IP65 | Stainless steel | 0.01 lx - 83865 lx | ± 0,2 % | | | t90 <7 s | -40 °F - 158 °F | Male connector M12 IEC 61076-2-101, 4-pole, A-coded | incl. pipe clip for screw fixing, Ø 3 mm | Ø 20 mm | Ø 20 mm | 1.6 in | 0.9 oz | 244445 | 244446 | 244447 | Cable 2.0 m, fully assembled with M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | Cable 5.0 m, for self-assembly, incl. M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | Cable 20.0 m, for self-assembly, incl. M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | | | SEN073-07302.0-00-Datasheet-EN-US.pdf |
07303.0-00 | Air quality, temperature | IP64 | Stainless steel | 0 VOC index - 500 VOC index | | 14 °F - 122 °F | ± 0,2 K | 1: t63 <10 s / 2: t63 <150 s | 14 °F - 122 °F | Male connector M12 IEC 61076-2-101, 4-pole, A-coded | incl. pipe clip for screw fixing, Ø 3 mm | Ø 20 mm | Ø 20 mm | 1.3 in | 0.9 oz | 244445 | 244446 | 244447 | Cable 2.0 m, fully assembled with M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | Cable 5.0 m, for self-assembly, incl. M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | Cable 20.0 m, for self-assembly, incl. M12 cable socket IEC 61076-2-101, 4-pole, A-coded, shielded | | | SEN073-07303.0-00-Datasheet-EN-US.pdf |