| 01260.0-01 | 恒温恒湿器 | II | IP20 | Plastic to UL94 V-0, light grey | Plastic fibre with progressive structure | G3 | 符合 UL94 V-0 标准的塑料,浅灰色 | AC/DC | 24 V - 240 V | 22 V - 265 V | 45-65 赫兹 | 1 W | 160 m³/h | 166 m³/h | 345 m³/h | 55 dB(A) | >30000 个周期 | -40 °C - 70 °C | ≤95 %相对湿度 | ≤95 %相对湿度 | -45 °C - 85 °C | 0,8 Nmmax. | 5 极接线端子,最大夹紧力矩 0.5 Nm:带 2.5 mm² (AWG 14)电线末端铁箍的多股线/绞合线 | 101 毫米 | 35 毫米 | 69,5 毫米 | 52 mm | 200 g | 246 x 246 mm | | | | | | | 开关欧姆负载(开关电感负载)。与多股线连接时必须使用电线末端铁箍。 | NEMA Type 12 | 06402.0-00 | Aluminium profile | 30 A | 16 A | 200 W | Connection terminal | 用于 35 毫米 DIN 导轨的夹子,符合 EN 60715 标准 | | | | | | | | | | | | | | | 3 s | 转换器 | Overheating protection in the event of fan failure with automatic reset, additional contactor with irreversible fuse | Plastic to UL94 V-0, black | 0 °C - 60 °C | 继电器 | 10 s | 13 A (CC) | 16 A | 240 VAC | 5.9 in | 2 K | ± 1 K | 发光二极管 | 120 VAC | 1,6 A | 240 VAC | 120 VAC | 0,6 A | 60 VDC | 50 %相对湿度 - 90 %相对湿度 | 4 %相对湿度 | ± 1 %相对湿度 | | | | |
| 01220.0-00 | Hygrostat | II | IP20 | Plastic to UL94 V-0, light grey | Plastic fibre with progressive structure | G3 | Plastic to UL94 V-0, light grey | AC;DC | 24 V - 240 V | AC 250 V (VDE), AC 120 V (UL) V | 45-65 赫兹 | 1 W | 160 m³/h | 137 m³/h | 300 m³/h | 55 dB(A) | >50000 cycles | 0 °C - 60 °C | ≤95 % RH | ≤95 % RH | -40 °C - 60 °C | 0,5 Nmmax. | 3-polige Klemme, Anzugsmoment 0,5 Nm max.:
Starrdrahtleitung 2,5 mm² (AWG 14)
Litzenleitung² 1,5 mm² (AWG 16) | 67 mm | 50 mm | 38 mm | 52 mm | 60 g | 246 x 246 mm | 267071 | 267072 | 267126 | external sensor, 1m | external sensor, 2m | external sensor, 3m | Switching differential referred to 50 % rH. Wire end ferrules must be used for connections with stranded wires. | NEMA Type 12 | 01250.0-00 | Aluminium profile | 16 A | 16 A | 200 W | Connection terminal | Clip for 35 mm DIN rail, EN 60715 | On/off switch and motion detector | LED | CH | 6000 - 7000 K | 560 Lm | 250 V | 10 A | Temperature, air humidity | Reverse polarity protection, short-circuit proof, overvoltage protection | -40 °C - 60 °C | ± 1 K | 0 % RH - 100 % RH | ± 4 % | ≤ 500 Ω | 3 s | Change-over contact | Overheating protection in the event of fan failure with automatic reset, additional contactor with irreversible fuse | Plastic to UL94 V-0, black | 35 % RH - 95 % RH | Snap-action contact | 10 s | AC 5 A;DC 20 W | 5 A | 250 VAC | 5.9 in | 4 % RH | ± 3 % RH | 发光二极管 | 120 VAC | 1,6 A | 240 VAC | 120 VAC | 0,6 A | 30 VDC | 50 %相对湿度 - 90 %相对湿度 | 4 %相对湿度 | ± 1 %相对湿度 | 20 V | 0,1 A | CQC | |
| 02034.0-00 | Convection heaters | I | IP66 | | | | | AC | 230 V | 208 V - 253 V | 50;60 Hz | | | | | | >50000 h | -76 °F - 185 °F | ≤90 % rF | ≤90 % rF | -76 °F - 185 °F | 0,8 Nmmax. | Halogen-free silicone cable 3 x 0.75 mm², 1 m | 9.4 in | 2.4 in | 4.7 in | | 60 oz | | 09024.0-00 | | | Screw fixing | | | Other voltages on request;When operating below AC/DC 140 V, the heating capacity is reduced by approx. 10 %. | | 16504.0-00 | Aluminium profile, silver anodised | 9 A | 2 A | 200 W | Connection cable | Clip for 35 mm DIN rail;Screw fixing | | | | | | | | | | | | | | | | | Protección contra sobrecalentamiento en caso de fallo del ventilador con reset automático | Plastic to UL94 V-0, black | | | | | | | 11.8 in | | | | | | | | | | | | | | | | |
| 02034.9-00 | Convection heaters | I | IP66 | | | | | AC | 120 V | 108 V - 132 V | 50;60 Hz | | | | | | >50000 h | -76 °F - 185 °F | ≤90 % rF | ≤90 % rF | -76 °F - 185 °F | 0,8 Nmmax. | Halogen-free silicone cable 3 x 0.75 mm², 1 m | 9.4 in | 2.4 in | 4.7 in | | 60 oz | | | | | | | | Calefacción con ventilador;La calefacción sólo debe funcionar en combinación con un ventilador. Existe peligro de sobrecalentamiento. | | | Aluminium profile, silver anodised | | 4 A | 200 W | Connection cable | Clip for 35 mm DIN rail;Screw fixing | | | | | | | | | | | | | | | | | Protección contra sobrecalentamiento en caso de fallo del ventilador con reset automático | Plástico según UL94 V-0, negro | | | | | | | 11.8 in | | | | | | | | | | | | | | | | |
| 02035.0-10 | Convection heaters | I | IP66 | | | | | AC | 230 V | 208 V - 253 V | 50;60 Hz | | | | | | >50000 h | -76 °F - 185 °F | ≤90 % rF | ≤90 % rF | -76 °F - 185 °F | 0,8 Nmmax. | Halogen-free silicone cable 3 x 0.75 mm², 1 m | 8.7 in | 3.1 in | 6.3 in | | 81.1 oz | | | | | | | | Calefacción con ventilador;La calefacción sólo debe funcionar en combinación con un ventilador. Existe peligro de sobrecalentamiento. | | | Aluminium profile, silver anodised | | 2.5 A | 250 W | Connection cable | Screw fixing | | | | | | | | | | | | | | | | | Protección contra sobrecalentamiento en caso de fallo del ventilador con reset automático | Plástico según UL94 V-0, negro | | | | | | | 10.8 in | | | | | | | | | | | | | | | | |
| 02035.9-10 | Convection heaters | I | IP66 | | | | | AC | 120 V | 108 V - 132 V | 50;60 Hz | | | | | | >50000 h | -76 °F - 185 °F | ≤90 % rF | ≤90 % rF | -76 °F - 185 °F | 0,8 Nmmax. | Halogen-free silicone cable 3 x 0.75 mm², 1 m | 8.7 in | 3.1 in | 6.3 in | | 81.1 oz | | | | | | | | Calefacción con ventilador;La calefacción sólo debe funcionar en combinación con un ventilador. Existe peligro de sobrecalentamiento. | | | Aluminium profile, silver anodised | | 5 A | 250 W | Connection cable | Screw fixing | | | | | | | | | | | | | | | | | Protección contra sobrecalentamiento en caso de fallo del ventilador con reset automático | Plástico según UL94 V-0, negro | | | | | | | 10.8 in | | | | | | | | | | | | | | | | |
| 13092.1-13 | Fan heater;DC applications;Integrated control;Touchsafe | II | IP20 | | Plastic fibre with progressive structure | G3 | Plastic to UL94 V-0, black | DC | 24 V | 22 V - 26 V | 50;60 Hz | 1 W | 160 m³/h | | 500 m³/h | 67 dB(A) | >50000 h | -45 °C - 70 °C | ≤90 % RH | ≤90 % RH | -45 °C - 70 °C | 0,8 Nmmax. | 2-pole "push-in" connection terminal Stranded wire1 1.5 mm² (AWG 16) with strain relief; max. 2.5 mm² (AWG 12) | 99 mm | 168 mm | 179 mm | 107 mm | 1300 g | 246 x 246 mm | 267071 | 267072 | 267126 | external sensor, 1m | external sensor, 2m | external sensor, 3m | Fan heater with thermostat;other designs (heating capacities, setting ranges) and operating voltage DC 48 V on request;tolerance ±1 K | | 06403.0-00 | Aluminium profile | 30 A | 16 A | 200 W | Connection terminal | Clip for 35 mm DIN rail;Screw fixing | | | | | | | | | | | | | | | | Fan heater with integrated thermostat with connection for external temperature sensor | Overheating protection in the event of fan failure with automatic reset, additional contactor with irreversible fuse | Plastic to UL94 V-0, black | -20 °C - 40 °C | MOSFET | 10 s | 11 A (CC) | 11 A | 20...56 VDC | 8.9 in | 3 K | | | | | | | | | | | | | | | |
| 13095.3-03 | Fan heater;DC applications;Integrated control;Touchsafe | II | IP20 | | Plastic fibre with progressive structure | G3 | Plastic to UL94 V-0, black | DC | 56 V | 61 V - 51 V | 50;60 Hz | 85 W | 160 m³/h | | 575 m³/h | 67 dB(A) | >50000 h | -45 °C - 70 °C | ≤90 % RH | ≤90 % RH | -45 °C - 70 °C | 0,8 Nmmax. | 2-pole "push-in" connection terminal Stranded wire1 1.5 mm² (AWG 16) with strain relief; max. 2.5 mm² (AWG 12) | 99 mm | 168 mm | 179 mm | 107 mm | 1300 g | 246 x 246 mm | 267071 | 267072 | 267126 | external sensor, 1m | external sensor, 2m | external sensor, 3m | Fan heater with thermostat;other designs (heating capacities, setting ranges) and operating voltage DC 48 V on request;tolerance ±1% rH | | 16501.0-00 | Aluminium profile | 2,5 A | 20 A | 600 W | Connection terminal | Clip for 35 mm DIN rail;Screw fixing | | | | | | | | | | | | | | | | Fan heater with integrated hygrostat with connection for external humidity sensor | Overheating protection in the event of fan failure with automatic reset, additional contactor with irreversible fuse | Plastic to UL94 V-0, black | 40 % RH - 90 % RH | | | | | | 8.9 in | 4 % RH | | | | | | | | | | | | | | | |
| 13097.3-12 | Fan heater;DC applications;Integrated control;Touchsafe | II | IP20 | | | | Plastic to UL94 V-0, black | DC | 56 V | 61 V - 51 V | 50;60 Hz | | 160 m³/h | | | | >50000 h | -45 °C - 70 °C | ≤90 % RH | ≤90 % RH | -45 °C - 70 °C | 0,8 Nmmax. | 2-pole "push-in" connection terminal Stranded wire1 1.5 mm² (AWG 16) with strain relief; max. 2.5 mm² (AWG 12) | 99 mm | 168 mm | 179 mm | | 1300 g | | | | | | | | Fan heater with thermostat;other designs (heating capacities, setting ranges) and operating voltage DC 48 V on request;tolerance ±1 K | | 16502.0-00 | Aluminium profile | 4 A | 20 A | 800 W | Connection terminal | Clip for 35 mm DIN rail;Screw fixing | | | | | | | | | | | | | | | | Fan heater with integrated thermostat with internal temperature sensor | Overheating protection in the event of fan failure with automatic reset, additional contactor with irreversible fuse | Plastic to UL94 V-0, black | -20 °C - 40 °C | | | | | | 8.9 in | 3 K | | | | | | | | | | | | | | | |
| 13097.3-13 | Fan heater;DC applications;Integrated control;Touchsafe | II | IP20 | | | | Plastic to UL94 V-0, black | DC | 56 V | 61 V - 51 V | 50;60 Hz | | 160 m³/h | | | | >50000 h | -45 °C - 70 °C | ≤90 % RH | ≤90 % RH | -45 °C - 70 °C | 0,8 Nmmax. | 2-pole "push-in" connection terminal Stranded wire1 1.5 mm² (AWG 16) with strain relief; max. 2.5 mm² (AWG 12) | 99 mm | 168 mm | 179 mm | | 1300 g | | 267071 | 267072 | 267126 | external sensor, 1m | external sensor, 2m | external sensor, 3m | Fan heater with thermostat;other designs (heating capacities, setting ranges) and operating voltage DC 48 V on request;tolerance ±1 K | | 16503.0-00 | Aluminium profile | 4,5 A | 20 A | 800 W | Connection terminal | Clip for 35 mm DIN rail;Screw fixing | | | | | | | | | | | | | | | | Fan heater with integrated thermostat with connection for external temperature sensor | Overheating protection in the event of fan failure with automatic reset, additional contactor with irreversible fuse | Plastic to UL94 V-0, black | -20 °C - 40 °C | | | | | | 8.9 in | 3 K | | | | | | | | | | | | | | | |