Electronic hygrotherm

ETF 012

The electronic hygrotherm simultaneously monitors temperature and air humidity in enclosures and cabinets. Condensation is avoided by switching the heating and fans as required. In the design with an external sensor, this can be placed anywhere in the enclosure and thus enables precise measurement.

  • Adjustable temperature and air humidity
  • Wide-range voltage
  • High switching capacity
  • Operating temperature down to -40 °C
  • Visual status display
CEUKCAEACULVDE

Overview technical data

Device typeHygrostat
Contact typeRelay
Protection typeIP20
Operating displayLED
CasingPlastic to UL94 V-0, light grey
Inrush current maximum30 A
Inrush current duration 10 s
Power consumption 1 W
Switching capacityAC 240 V, 10 (1.6) A DC 30 W, DC 60 V, 0.6 A
Switching current ohmic 10 A
Reference voltage ohmic maximum240 VAC
Reference voltage 2 ohmic maximum120 VAC
Switching current inductive 1.6 A
Reference voltage inductive maximum240 VAC
Reference voltage 2 maximum120 VAC
Switching current dc ohmic 0.6 A
Reference voltage dc ohmic maximum60 VDC
Reaction time 5 s
Service lifeVDE: >15000 cycles UL: >30000 cycles
setting_range_250 % RH - 90 % RH
Switching differential 2 K
Switching differential tolerance ± 1 K
Switching differential 2 4 % RH
Switching differential 2 tolerance ± 1 % RH
Operating temperature-40 °C - 60 °C
Operating humidity ≤90 % RH
Storage humidity ≤90 % RH
Storage temperature-40 °C - 60 °C
Torque 0.5 Nmmax.
Connection5-pole clamp, torque 0.5 Nm max.: Rigid wire/stranded wire with 2.5 mm² wire end ferrule (AWG 14)
DesignChanger
MountingClip for 35 mm DIN rail, EN 60715
Height 77 mm
Width 60 mm
Depth 43 mm
Weight 200 g
NoteSwitching resistive load (switching inductive load). Wire end ferrules must be used for connections with stranded wires.

Product variants

Article numberSetting rangeExternal sensorAC/DCOperating voltageOperating voltage toleranceRequestCADDatasheet
01230.0-000 °C - 60 °CAC100 V - 240 V90 V - 265 V
ETF012-01230.0-00-Datasheet-EN-GB.pdf
01230.9-0032 °F - 140 °FAC100 V - 240 V90 V - 265 V
ETF012-01230.9-00-Datasheet-EN-GB.pdf
01231.0-010 °C - 60 °CExternal hygrotherm sensor with 2 m cableAC100 V - 240 V90 V - 265 V
ETF012-01231.0-01-Datasheet-EN-GB.pdf
01231.0-000 °C - 60 °CExternal hygrotherm sensor with 1 m cableAC100 V - 240 V90 V - 265 V
ETF012-01231.0-00-Datasheet-EN-GB.pdf
01230.1-000 °C - 60 °CDC24 V - 48 V20 V - 60 V
ETF012-01230.1-00-Datasheet-EN-GB.pdf
01231.9-0132 °F - 140 °FExternal hygrotherm sensor with 2 m cableAC100 V - 240 V90 V - 265 V
ETF012-01231.9-01-Datasheet-EN-GB.pdf
01231.9-0032 °F - 140 °FExternal hygrotherm sensor with 1 m cableAC100 V - 240 V90 V - 265 V
ETF012-01231.9-00-Datasheet-EN-GB.pdf
01231.1-000 °C - 60 °CExternal hygrotherm sensor with 1 m cableDC24 V - 48 V20 V - 60 V
ETF012-01231.1-00-Datasheet-EN-GB.pdf
01231.1-010 °C - 60 °CExternal hygrotherm sensor with 2 m cableDC24 V - 48 V20 V - 60 V
ETF012-01231.1-01-Datasheet-EN-GB.pdf