3040




IO-LINK ACTUATOR HUB
AHC 072 | DC 24 V | 3 Relay Outputs
The IO-Link Actuator Hub AHC 072 can switch up to three actuators or loads on process level via relays. Switching commands for the loads are received via the IO-Link interface from a higher-level control unit: edge computer, cloud, PLC control, etc. The actuator hub supports both AC and DC loads, independent of their function or whether they have a communication interface.
- Digital IO-Link interface
- Easy DIN rail or screw mounting
- M12 plug-in connector
- For 1 to 3 actuators
- Quick connection for actuators via Push-In terminals
- Optical indicators (LEDs)
Overview Technical Data
1 to 3 contact makers (NO), with 3 optical indicators
AC 240 V, 10 A
DC 30 V, 10 A
DC 30 V, 10 A
AC 16 A for 10 s
2-pole Push-In terminals (3 x)
IO-Link (version 1.1)
M12 round plug connector, IEC 61076-2-101, 4-pin, A-coded
Reverse-polarity, short circuit, overvoltage protection
clip for 35 mm DIN rail, EN 60715 and
screw mounting (M5)
screw mounting (M5)
plastic according to UL94 V-0, light grey
107 x 35 x 108 mm (116 mm with universal mounting bracket)
~ 160 g
variable
-40 to +70 °C (-40 to +158 °F) with 3 outputs with 2 A load each
1-40 to +40 °C (-40 to +104 °F) with 3 outputs with 10 A load each¹
1-40 to +40 °C (-40 to +104 °F) with 3 outputs with 10 A load each¹
-40 to +85 °C (-40 to +185 °F)
< 90 % RH (non-condensing)
≤ 4000 m above sea leavel
IP40 / III (SELV)
CB No. DE1-63389
in conformity with IEC 61010-1
evaluated according to UL and CSA standards
in conformity with IEC 61010-1
evaluated according to UL and CSA standards
1 The max. operating temperature depends on the current (see diagram) and the number of loads.
Product Variants
Summary of your request
Art. No. | Connection casing | Casing | Productname | Series | Heating element | Heater body | Model | Axial fan | Operating voltage |
Operating voltage max. |
Operating voltage min. |
Voltage type | Frequency | Heating capacity |
Inrush current max. |
Surface temperature |
Rec. pre-fuse T (time-delay) |
Connection | Connection PE | Air outlet temperature | Switch-off temperature | Switch-off temperature 2 | Switch-on temperature | Switch-on temperature 2 | Drilling template | Operating temperature |
Flow rate, free flow |
Flow rate, with filter |
Setting range | Setting range 2 |
Current consumption |
Nominal current of socket |
Power consumption |
Average noise level | Enclosure cut-out | Enclosure cut-out | Storage temperature | Storage humidity | Ambient temperature | Operating humidity | Speed |
Switching capacity max. |
Switching current min. |
Load resistance (external) | External Sensor | Measuring range | Measuring range 2 | Note | Note 2 | Note 3 | Note 4 | Reaction time | Contact type | Service life | Operation indicator |
Control contact - Signal current |
Electrical protection | Switch | Socket | Material | Material sealing | Air permeability | Mounting | Air intake/Air outlet | Filter material | Measuring signal |
Switch temperature difference |
Lamp type | Luminous flux | Light colour | Length / Depth | Width | Height | Diameter | Installation depth | Fitting position | Mounting frame | Weight | Sensor element | Protection class | Protection type | Protection type UL | VDE | UL | EAC | METRO | ATEX | Ex Protection type Gases | Ex Protection type Mine applications | Ex Protection type Dusts | Temperature class |
Temperature safety cut-out |
Accessory | Accessory 2 | Accessory 3 | Accessory 4 | Art. No. Accessory | Art. No. Accessory 2 | Art. No. Accessory 3 | Art. No. Accessory 4 | Catalogue Article | CAD |
---|
Everything from one source
Further products
Heating
Prevent subnormal temperatures and condensation using enclosure heaters, either with or without fans.

Cooling
Achieve perfect enclosure cooling, even in systems tightly fitted with components, using filter fans and fans.

Stego Connect